Directory · Dallas
Dallas commercial kitchen hood cleaning
Research index for operators. Public rules we found, how to vet a cleaner, open listing slots. Not a ranked vendor list.
Who the AHJ is
- Dallas Fire-Rescue, Inspection & Life Safety Education Division (under the Fire Marshal / Prevention and Investigation Bureau): 1551 Baylor St., Suite 400, Dallas, TX 75226; main office 214-670-4319.
- Dallas adopted the 2021 International Fire Code with Dallas amendments (effective February 10, 2023) and the 2021 International Mechanical Code with Dallas amendments (effective May 12, 2023). Confirm the current edition with your inspector if amendments have moved since.
- Building Inspection still lists commercial kitchen exhaust / grease duct rough inspections among mechanical inspections; Fire Protection plan review contacts change — verify on the live city site before dialing older published numbers.
Inspection intervals (Dallas Fire Code Table 606.3.3.1)
| Type of cooking operations | Frequency of inspection |
|---|---|
| Cooking operations utilizing solid fuel-burning cooking appliances | 1 month |
| High-volume cooking operations such as 24-hour cooking, charbroiling or wok cooking | 3 months |
| All other cooking operations | 6 months |
| Low-volume cooking operations such as places of religious worship, seasonal businesses and senior centers | 12 months |
- Inspections are by qualified individuals (§606.3.3.1). If grease has accumulated, components are cleaned in accordance with ANSI/IKECA C10 (§606.3.3.2).
- Inspection and cleaning records must identify the individual and company and the date; keep them after each visit (§606.3.3.3).
- After an inspection, a tag with the service provider name, address, telephone number, and date of service goes in a conspicuous location; prior tags are covered or removed (§606.3.3.3.1).
- Dallas Fire-Rescue’s public assembly checklist also states: maintain stove and vent hoods free of grease (DFC 606.3.3.2). See inspection frequency and inspection vs cleaning.
Suppression and Class K
- Fire-extinguishing systems must protect commercial cooking that produces grease-laden vapors (DFC 904.13).
- If the hood has a fire-extinguishing system, provide one Class K extinguisher within 30 feet (DFC 906.4.3).
- Systems are serviced at least every 6 months and after activation (DFC 904.13.5.2). That is a separate contractor track from grease cleaning. See suppression vs hood cleaning.
Reinspection fees
Dallas Fire-Rescue’s public assembly occupancy checklist (revised August 26, 2024) and Dallas Fire Code §107.7 schedule:
| Reinspection | Fee |
|---|---|
| Initial inspection | No charge (per fire checklist) |
| 1st reinspection | $171 |
| 2nd reinspection | $200 |
| 3rd and each subsequent | $255 |
Exceptions in the code text include certain residential situations and construction under a valid building permit. Confirm current amounts before you budget a return visit. See how to research reinspection fees and what a reinspection notice usually cites.
Grease traps: Dallas Water Utilities (not the fire code)
FOG rules come from the sewer side. Hood wash water still ends up in the interceptor.
- Food service grease traps/interceptors must be 100% pumped out at least the earlier of every 90 days, or when floating materials, sediment, oils, or grease reach 25% or more of the wetted height (Dallas City Code §19-126.2).
- A trap/interceptor permit is required for food service establishments using a grease or sand trap/interceptor (§19-126.3).
- Producers keep manifests on site for three years and use a city-permitted liquid waste transporter (§19-126.1, §19-126.5).
- Ask your hood cleaner where wash water goes — interceptor, not the storm drain. See chemical runoff and grease waste.
Fort Worth: same cleaning table, different paperwork
Fort Worth Fire Department’s Bureau of Fire Prevention runs its own fire code. The cleaning rule matches Dallas; the reporting and permit side does not.
- Code. Fort Worth adopted the 2021 International Fire Code with local amendments (Ordinance No. 25388-03-2022). Its Table 606.3.3.1 carries the same intervals as Dallas: 1 month for solid fuel, 3 months for high-volume (24-hour, charbroiling, wok), 6 months for all other cooking, 12 months for low-volume. Grease found on inspection is cleaned per ANSI/IKECA C10, with records naming the individual, the company and the date.
- Reports go to The Compliance Engine. Since December 15, 2024, service providers who inspect or test fire protection systems in Fort Worth must submit every test, inspection and service report, pass or fail, through The Compliance Engine (Brycer). Kitchen hood suppression reports use the Kitchen Hood template, and deficiencies are tracked there until corrected. The contractor pays a filing fee per report; Fort Worth does not publish the amount on its own pages, so expect it as a line on the suppression invoice and ask what it is.
- What the inspector checks. Fort Worth’s self-inspection checklist (updated May 10, 2024) asks for a hood suppression system inspected and tagged by a state-licensed extinguishing contractor within the last six months, a hood that is clean and free of grease build-up, and a Class K wet chemical extinguisher within 30 feet.
- New or replaced suppression. The 2021 Fort Worth Fire Code Appendix I lists a construction permit of $200 per kitchen hood with a pre-engineered extinguishing system, plus $110 per hour for each inspection after the first. Fort Worth adopted a new fee ordinance (No. 26-28781) effective October 1, 2026 that raises most fire fees by about 5%; confirm the current figure before you budget.
- Contacts. Commercial inspection questions: fireinspections@fortworthtexas.gov. Extinguishing system inspection requests: 817-392-6844. Bureau of Fire Prevention: 817-392-6840.
- Other suburbs. The Metroplex cities each run their own fire marshal office. The section below covers Irving, Plano and Frisco; for anywhere else, ask which code edition it enforces and whether it uses The Compliance Engine.
Irving, Plano and Frisco: who gets the report
Three of the busiest suburban restaurant markets handle hood paperwork three different ways. What we found on each city’s own pages:
| City | Where hood reports go | What it means for your quote |
|---|---|---|
| Irving | The Compliance Engine. Irving Fire Department’s service provider letter (March 5, 2026) requires every test, inspection, deficiency and service report, pass or fail, to be filed electronically. Kitchen Hood Suppression and Kitchen Hood Cleaning are both on its list of tracked systems. | Your hood cleaner, not only your suppression company, files a report. The contractor pays a filing fee per report; Irving does not publish the amount, so ask whether it is in the price. |
| Plano | No city-wide electronic filing requirement found. Fire Prevention schedules kitchen hood suppression inspections through its online Inspection Request Form. | Keep the cleaning and suppression reports on site for the inspector. Inspections run Monday–Friday, 6:30 a.m.–4 p.m.; after-hours inspections carry a fee. |
| Frisco | No electronic filing requirement found. The Fire Prevention Office inspects hood suppression at the fire final and inspects existing systems on request. | For a new or changed system, the inspection covers an air test, utility shunt, manual pull, exhaust and make-up air, fire alarm notification, and a Class K extinguisher within 30 feet of cooking appliances. After-hours inspections need 48 hours’ notice and may cost extra. |
- Irving contacts. Fire Prevention, 845 W. Irving Blvd.: 972-721-2651, fireinspections@irvingtx.gov.
- Plano contacts. Fire Prevention (cancel or change an inspection): 972-941-7159. A representative of the requesting company must be on site for the inspection.
- Frisco contacts. Inspections@FriscoFire.com. Contractors report system impairments through the city’s Contractor System Impairment Reporting form.
- Arlington. Fire Prevention is at 405 W. Main St., 817-459-5539. We have not confirmed on a city page whether Arlington requires hood reports to be filed electronically; ask before you sign.
Three separate jobs in a Dallas kitchen
| Job | Rule we found | Proof |
|---|---|---|
| Hood, duct, and fan inspection and cleaning | DFC Table 606.3.3.1; clean per ANSI/IKECA C10 when grease found | Records + service tag on the hood |
| Hood suppression service | DFC 904.13.5.2 — at least every 6 months and after activation | Service tag less than six months old |
| Grease trap / interceptor | §19-126.2 — 90 days or 25% rule; permit required | Manifests (3 years) + trap permit |
Vet checklist
- Certs your AHJ accepts (IKECA C10 cleaning method is cited in the fire code — ask how they document it)
- Certificate of insurance before they arrive
- Photo report: plenum, ducts, rooftop fan, grease receptacle — not only the canopy
- Full-system vs canopy wipe in writing, with inaccessible areas listed
- Service tag left with company name, address, phone, and date
- Wash water routed to the grease interceptor
- After-hours and roof access confirmed before the crew shows up
Before you ask for quotes
- Say whether the kitchen is in Dallas, Fort Worth or another Metroplex city, since the fire office and reporting rules differ.
- Have your cooking type ready (solid fuel, charbroil/wok/24-hour, or standard) so the cleaner can quote the right interval.
- Count hoods, fans and any long horizontal duct runs, and note roof access.
- Bring the date and company on your last cleaning tag and last suppression tag.
- In Fort Worth or Irving, ask whether the price includes the Compliance Engine filing fee. In Irving that applies to the hood cleaning report as well as the suppression report.
- For a new or changed system in Frisco or Plano, ask who books and attends the fire inspection; both cities need a representative of the requesting company on site.
- List open fire inspection items so the quote covers what the inspector wrote up.
Open listing slots
Sources
- Dallas Fire Code 2021 Chapter 6 (UpCodes) (Table 606.3.3.1; §606.3.3.2 ANSI/IKECA C10; records and tags)
- Dallas Fire-Rescue: Public assembly occupancy checklist (PDF, revised Aug 26, 2024) (kitchen items; reinspection fee amounts; contact)
- Dallas ordinance PDF — Fire Code §107.7 reinspection fee schedule ($171 / $200 / $255)
- Dallas City Code §19-126.2 traps/interceptors required (90-day / 25% pumping rule)
- Fort Worth Fire Code 2021 Chapter 6 (UpCodes) (Table 606.3.3.1; ANSI/IKECA C10; records)
- Fort Worth Fire Code 2021 Appendix I (UpCodes) ($200 per hood pre-engineered extinguishing system; $110/hr additional inspections)
- Fort Worth Bureau of Fire Prevention (2021 IFC adoption; fee ordinance 26-28781 eff. Oct 1, 2026; contacts)
- Fort Worth Fire Department: Compliance Engine letter (PDF) (electronic reports required from Dec 15, 2024)
- Fort Worth fire safety self-inspection checklist (PDF, updated May 10, 2024) (item 21: hood, suppression tag, Class K)
- Irving Fire Department: Inspections Reporting Letter (PDF, March 5, 2026) (Compliance Engine; kitchen hood suppression and kitchen hood cleaning tracked; contractor filing fee)
- Irving Fire Prevention: Inspections (contacts)
- Plano Fire Prevention: Inspection Request Form (kitchen hood suppression; hours; after-hours fee; 972-941-7159)
- Frisco Fire Prevention Office: Inspections (hours; after-hours notice; contact)
- Frisco Fire Department: Kitchen Hood Suppression System checklist (PDF, rev. June 2018)
- Arlington Fire Prevention Division (address and phone)
- Dallas Code of Ordinances (AmLegal library)
Related guides
- How often to inspect
- Full-system vs canopy wipe
- What your report must show
- Fire marshal reinspection fee research
- Grease leaking from the rooftop fan
- Quote checklist
- Austin · Houston · Kansas City · San Antonio
Request a listing — company, metro, certs, insurance, service area, photo-report policy.
Get quotes from local hood cleaners
Tell us about your kitchen and we'll pass the request to up to 3 local providers in Dallas. No cost to you, no obligation.