Directory · Chicago
Chicago commercial kitchen hood cleaning
Research index for operators. Public rules we found, how to vet a cleaner, open listing slots. Not a ranked vendor list.
No Chicago cleaning interval in the code: Chicago’s fire code adopts the IFC but leaves out the chapter that holds the hood-cleaning interval table, and we found no city table to replace it. Vendors work from NFPA 96. Get the cadence your CFD inspector expects in writing.
What operators usually get asked
- Chicago Municipal Code 18-28-507: Type I or Type II hoods over commercial food heat-processing appliances; Type I where grease vapors or smoke are produced; solid-fuel Type I hoods discharge to an independent exhaust system.
- Mobile food / shared-kitchen rules define NFPA 96, require automatic suppression maintained per NFPA 96, and state semi-annual hood inspection by a licensed HVAC professional for certain mobile setups. That mobile rule is not automatically the brick-and-mortar cadence — verify fixed restaurants with CFD Fire Prevention.
- Kitchen hoods may need Air Pollution Control permitting (Form FP) when regulated — separate from grease cleaning.
- No useful public chicago.gov page stating a fixed brick-and-mortar grease-cleaning interval table was located. Confirm intervals and documentation with CFD Fire Prevention Bureau.
Why Chicago has no IFC-style interval table
Many cities on this site (Houston, Phoenix, Nashville, Portland) enforce IFC Table 606.3.3.1: monthly for solid fuel, quarterly for high-volume, semi-annual for most kitchens, annual for low-volume. Chicago is different.
- The 2019 ordinance that created Title 14F adopted the 2018 IFC only in part. Its §14F-6-600 says IFC Chapter 6 is not adopted, and that building services and systems are built and maintained under the other Chicago Construction Codes. Section 606, including the inspection table, is in Chapter 6.
- The City Council rewrote Title 14F on June 17, 2026 and renamed it the “2026 Interim Fire Prevention Code.” Section 14F-1-001 now adopts the 2024 IFC by reference, still only “to the extent specified.”
- Chapter 6 in the 2026 version, as published on UpCodes (checked 2026-10-18), still carries one line: §601.1, building services and systems are provided and maintained under the other Chicago Construction Codes. No Section 606 text and no interval table appear. So the move to the 2024 IFC did not bring the IFC cleaning schedule into Chicago’s code as far as we can read. Ask CFD Fire Prevention which document their inspector cites.
- In practice, Chicago vendors quote NFPA 96 inspection schedules (monthly / quarterly / semi-annual / annual by cooking volume). That is the vendor’s reference, not a Chicago table. Get the cadence the inspector expects in writing.
- The same 2019 ordinance requires each Type I hood and duct system to be protected by an automatic fire-extinguishing system (§904.2.2 as amended). That’s the suppression contractor’s job, not the cleaner’s.
Duct rules a Chicago cleaner should flag
Chicago Municipal Code 18-28-506.3.8 (prevention of grease accumulation) sets duct details a good crew notices and writes up:
| Rule | What to look for on the report |
|---|---|
| Type I ducts built so grease can’t collect anywhere | Pooled grease in low spots or sags means a slope or support problem, not just a dirty duct |
| Slope at least 1/4 in. per foot (2%) toward the hood or an approved grease reservoir | Grease running away from the hood, or collecting at a horizontal run |
| Horizontal runs over 75 ft: at least 1 in. per foot (8.3%) | Long food-hall or mall runs that hold grease mid-span |
| Fan discharge can’t hit the roof, equipment, or structure | Grease staining on the roof membrane or nearby units |
| Vertical discharge fans need a drain outlet at the housing bottom to an approved grease reservoir | Missing or plugged drain, overflowing grease cup (see grease cup inspection points) |
Grease duct clearance to combustibles is 18 in. unless it’s a listed factory-built duct. Wrapped or shafted ducts need access doors through the enclosure (see fire wrap and enclosures).
2026 code change: remodels and new hoods
Chicago adopted Phase 3 of its construction codes modernization on June 17, 2026, including a new 2026 Chicago Mechanical Code (Title 14M). Department of Buildings Code Memorandum 2026-001 says using the 2026 ordinance is optional for permit applications as of October 1, 2026 and mandatory for applications started on or after December 1, 2026. Drawings must carry a “2026 Chicago Mechanical & Energy Codes” label. This matters if you’re adding or moving a hood. It doesn’t change how often an existing hood gets cleaned. See makeup air and exhaust balance for when the job is HVAC, not cleaning.
CFD inspections and fees
- Municipal Code §15-4-030 requires the Fire Department to inspect Group A (assembly) occupancies every year. Under the building code, restaurants and bars above the assembly occupant-load threshold fall in Group A. Ask CFD how your space is classed if you’re not sure.
- Other buildings over one story, with some residential exceptions, are inspected “periodically and as often as necessary.”
- The same section sets the inspection fee at $500, or $2,300 for a high-rise. The section was last amended by Council action on 12-19-25 and 6-17-26.
- CFD’s Fire Prevention Bureau runs four area offices (North, South, West, Central) that handle these annual general inspections. Keep the last cleaning report and the hood label where you can show them.
- Reinspection fee: Unknown. We did not find a separate one in §15-4-030. Ask when the inspector schedules you.
Grease interceptors: a separate trade with its own records
- Chicago’s plumbing code (§18-29-1003.3.1) requires a grease interceptor or automatic grease removal device on grease-laden drains in commercial kitchens. The listed fixtures include pot and prerinse sinks, wok stations, floor drains that take kettle drainage, dishwashers without a prerinse sink, and automatic hood wash units. If your hood has a built-in wash system, its drain belongs on the interceptor.
- Food waste disposers may not discharge to the interceptor (§18-29-1003.3.2). Enzyme, emulsifier, and chemical dosing systems are prohibited; only listed microbial systems the interceptor maker allows are permitted (§18-29-1003.3.3).
- No fixed pump-out interval appears in the city code. §18-29-1003.13 requires removing grease and solids “as often as necessary to ensure efficient operation,” and the owner must keep a written maintenance record for the life of the unit or five years, whichever is longer, available to the Departments of Buildings and Water Management on request.
- The Metropolitan Water Reclamation District’s Sewage and Waste Control Ordinance (amended February 5, 2026) sets a 250 mg/L limit for total fats, oils and grease in discharges to its system.
- None of this covers the hood, duct, or rooftop fan. Interceptor pumping and hood cleaning are different jobs with different paperwork. See grease trap service on hood day.
Suburbs: where the hood report goes
Outside the city, your fire code official is the village fire department or a fire protection district, and many of them do adopt IFC Chapter 6. Several now require contractors to upload reports to Brycer’s The Compliance Engine instead of leaving them only in your binder. What each office publishes:
| Fire code official | Code / what applies | Hood report filing |
|---|---|---|
| Western Springs Department of Fire & EMS, 708-246-1800 | Reports collected under IFC 2018 §108.3, which lets the fire code official require records to be filed. | Service companies submit through The Compliance Engine. The tracked list includes semi-annual kitchen hood cleaning and annual/semi-annual hood suppression. Deadlines: compliant reports within 30 days, deficient within 5 days, critical deficiencies reported to the department immediately and uploaded within 24 hours. Owners and managers can request view-only access at fireinfo@wsprings.com. |
| Deerfield Bannockburn Fire Protection District, 847-945-4066 | District fire prevention bureau. | Uses The Compliance Engine (LIVsafe) for inspection, testing and maintenance records, including commercial kitchen exhaust systems and cleaning and hood suppression. |
| Countryside Fire Protection District (Vernon Hills area), 847-367-5511 | District fire prevention bureau; inspects about 1,200 commercial, educational and multifamily occupancies. | Compliance Engine reports required for systems including commercial kitchen exhaust cleaning and hood suppression. |
| Village of Palatine Fire Prevention Division | Enforces ITM requirements under the 2021 IFC. | Contractors must upload all compliant and non-compliant reports to The Compliance Engine. The published tracked list names hood suppression systems; it does not list exhaust cleaning, so ask the inspector whether cleaning reports are expected there too. |
| Evanston Fire Department, 847-448-8191 | Lists the 2021 IFC among adopted codes. A separate fire department permit is required before installing or modifying a kitchen hood suppression system; a building permit does not cover it. Submittals go to efdplanreview@cityofevanston.org; inspections are scheduled through 311 at 847-866-4311. | We found no published hood report filing rule. Keep the cleaning report and service label on site. |
Where a district tracks exhaust cleaning in The Compliance Engine, an unfiled report can show your kitchen as overdue even after a good cleaning. Ask the cleaner to confirm in writing that they are registered with your department’s portal and will file for your address, and whether a filing fee appears on your invoice. Houston’s suburbs (Sugar Land, Fort Bend County) and Nashville’s (Brentwood, Gallatin) work the same way. Naperville, Schaumburg, Oak Park, Aurora and other suburbs were not checked. Call your own fire prevention bureau.
Before you call for a quote
- Pick your cooking volume. Because Chicago has no city table, the quote will follow NFPA 96: monthly for solid fuel, quarterly for high-volume (24-hour, charbroil, wok), semi-annual for moderate volume, annual for low volume (see how often to inspect).
- Read the date and company off the service label on the hood, and find the last report. Grease load is one of the main things that moves a quote (see what drives quote variance).
- Say who is asking: a CFD annual inspection, a CDPH health inspection, an insurer, or a landlord, so the cleaner knows what paperwork to leave you.
- Count hoods and describe the roof: fan location, roof hatch or ladder, and whether a long horizontal run (food halls, mall and high-rise kitchens) has access panels.
- Ask the crew to write up any duct sag, pooled grease, or missing fan drain under §18-28-506.3.8, and to list anything not cleaned and why, with before-and-after photos of the duct and fan.
- Ask whether the crew coordinates with your licensed suppression company, and where the wash water goes.
- In the suburbs, find out whether your fire department or district wants hood cleaning reports filed through The Compliance Engine, and make filing part of the quote (suburb rules).
Vet checklist
- Certs your AHJ accepts (IKECA or local equivalent) — ask, then verify
- Certificate of insurance before they arrive
- Photo report: plenum, ducts, rooftop fan — not only the canopy
- Full-system vs canopy wipe in writing
- Written note on any duct sag, pooled grease, or missing fan drain (18-28-506.3.8)
- After-hours and roof access confirmed before the crew shows up
Open listing slots
Sources
- Chicago Mun. Code 18-28-507 (AmLegal)
- Mobile food / shared kitchen rules (PDF)
- APC permit guide (PDF)
- Chicago building code portal
- UL 710 commercial cooking hoods memo (PDF)
- 2019 Chicago Construction Codes ordinance (PDF) (Article VII: Title 14F adopts 2018 IFC in part; §14F-6-600 does not adopt IFC Ch. 6; §904.2.2 Type I hood suppression)
- Title 14F, 2026 Interim Fire Prevention Code (AmLegal) (renamed by Coun. J. 6-17-26)
- Chicago Mun. Code 18-28-506.3.8 Prevention of grease accumulation (AmLegal)
- DOB Code Memorandum 2026-001: Transition to the 2026 Construction Codes (PDF)
- UpCodes: Chicago 18-28-506 commercial kitchen grease ducts (18 in. clearance to combustibles; listed factory-built duct exception)
- HOODZ of Downtown Chicago: NFPA standards (example of a Chicago vendor quoting the NFPA 96 inspection schedule; secondary)
- UpCodes: Chicago Fire Code 2024, Chapter 6 (§601.1 only; checked 2026-10-18)
- Chicago Mun. Code 15-4-030 Inspections: Group A annual, $500 / $2,300 high-rise (AmLegal)
- Chicago Mun. Code 18-29-1003.3 Grease interceptors (AmLegal)
- Chicago Mun. Code 18-29-1003.13 Access and maintenance of interceptors; 5-year records (AmLegal)
- MWRD Sewage and Waste Control Ordinance, amended Feb. 5, 2026 (PDF)
- Western Springs Department of Fire & EMS: Fire protection systems ITM (Compliance Engine; semi-annual kitchen hood cleaning; 30-day / 5-day / 24-hour submission time frames)
- Deerfield Bannockburn FPD: Reporting compliance (commercial kitchen exhaust systems and cleaning tracked)
- Countryside FPD: Fire prevention (Compliance Engine; commercial kitchen exhaust cleaning tracked)
- Village of Palatine: Inspection, testing, and maintenance requirements (2021 IFC; Compliance Engine; hood suppression tracked)
- Evanston Fire Department: Fire Prevention Bureau information package (PDF) (2021 IFC adopted; separate hood suppression permit)
- Chicago Fire Department: Fire Prevention (four area offices; annual inspections)
Related guides
- How often to inspect
- Full-system vs canopy wipe
- What your report must show
- Quote checklist
- Grease trap service on hood day
- What a full-system clean includes
- Minneapolis · Detroit · Kansas City
- Horizontal duct runs and panel spacing
- Nashville (suburban report portals)
Request a listing — company, metro, certs, insurance, service area, photo-report policy.
Get quotes from local hood cleaners
Tell us about your kitchen and we'll pass the request to up to 3 local providers in Chicago. No cost to you, no obligation.